1xEV-DO Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
147
User Manual 1173.9511.02 ─ 11
Suffix:
<n>
.
4, 6
Return values:
<IPAddress>
IP address/prefix as string
Example:
See
Usage:
Query only
Firmware/Software:
V3.0.11
Manual operation:
See
"AT IPv4 Address, IPv6 Prefix"
2.6.4 Instance Pre-Selection
Some remote commands operate on a pre-selected object instance that has to be
specified before the command is executed. The following "SETTing" commands imple-
ment this kind of instance pre-selection.
CONFigure:EVDO:SIGN<i>:SECTor:SETTing
...................................................................147
CONFigure:EVDO:SIGN<i>:CARRier:SETTing
................................................................. 147
CONFigure:EVDO:SIGN<i>:PILot:SETTing
.......................................................................148
CONFigure:EVDO:SIGN<i>:SECTor:SETTing
<SetSector>
Sets/gets the sector to which subsequent sector-related commands apply.
Parameters:
<SetSector>
Only sector 0 supported in the current release
Range:
0 to 0
*RST:
0
Example:
See
Firmware/Software:
V2.1.20
Options:
R&S CMW-KS881
Manual operation:
See
CONFigure:EVDO:SIGN<i>:CARRier:SETTing
<SetCarrier>
Sets/gets the carrier to which subsequent CARRier-related commands shall apply.
Parameters:
<SetCarrier>
Range:
0 to 2
*RST:
0
Example:
See
Firmware/Software:
V2.1.20
Options:
R&S CMW-KS881
Manual operation:
See
Command Reference
深圳德标仪器