CDMA2000 Measurements
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
771
User Manual 1173.9511.02 ─ 11
●
There are two groups of
FETCh
commands. One for result retrieval per segment
and one for result retrieval over all segments. Which of the two groups is more
effective, depends on the enabled results and on the number of segments. Mini-
mize the number of
FETCh
commands transmitted for result query.
●
To reset the system repeatedly, use partial reset commands instead of the global
reset command
*RST
. Example: Use
SYSTem:RESet 'CDMA Meas1'
to reset
the CDMA2000 measurement instance 1.
●
To configure the same list mode settings repeatedly, use partial save/recall com-
mands:
–
Configure all list mode settings once.
–
Save the list mode settings to a file, for example to the file
ListModeCDMA1.dfl
located in the directory assigned to the
@SAVE
alias:
MMEMory:STORe:ITEM 'CDMA Meas:MEV:LIST',
'@SAVE\ListModeCDMA1.dfl'
–
If you want to configure the same settings again, recall the stored settings:
MMEMory:LOAD:ITEM 'CDMA Meas:MEV:LIST',
'@SAVE\ListModeCDMA1.dfl'
Specifying General Measurement Settings
...........................................................771
Specifying Measurement-Specific Settings
...........................................................771
Performing Single-Shot Measurements
................................................................ 772
5.4.2.1
Specifying General Measurement Settings
//*************************************************************************
// System-Reset
//*************************************************************************
SYSTem:RESet 'CDMA Meas1'; *OPC?
*CLS; *OPC?
//*************************************************************************
// Define signal routing and external attenuation
//*************************************************************************
ROUTe:CDMA:MEAS:SCENario:SALone RF1C, RX1
CONFigure:CDMA:MEAS:RFSettings:EATTenuation 2
WAITKEY >Signal routing and analyzer settings completed, press "OK" to continue<
5.4.2.2
Specifying Measurement-Specific Settings
//*************************************************************************
// Define two segments with a length of 20 slots each
// and different analyzer settings.
//*************************************************************************
CONFigure:CDMA:MEAS:MEValuation:LIST:COUNt 2
CONFigure:CDMA:MEAS:MEValuation:LIST:SEGMent1:SETup 20,1,
833.49E+6,OFF,R36H,R11
CONFigure:CDMA:MEAS:MEValuation:LIST:SEGMent2:SETup 20, -10,
Programming