1xEV-DO Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
155
User Manual 1173.9511.02 ─ 11
Parameters:
<RXConnector>
RF1C | RF2C | RF3C | RF4C | RFAC | RFBC
RF connector for the input path
<RXConverter>
RX1 | RX2 | RX3 | RX4
RX module for the input path
<TXConnector>
RF1C | RF1O | RF2C | RF3C | RF3O | RF4C | RFAC | RFAO |
RFBC
RF connector for the output path
<TXConverter>
TX1 | TX2 | TX3 | TX4
TX module for the output path
Example:
See
Firmware/Software:
V3.2.10
Options:
R&S CMW-KS888
Manual operation:
See
ROUTe:EVDO:SIGN<i>:SCENario:SCFading:INTernal
<RXConnector>,
<RXConverter>, <TXConnector>, <TXConverter>
Activates the "Standard Cell Fading: Internal" scenario and selects the RF input (RX)
and output (TX) path, i.e. RF connectors and RX/TX modules. To query the active sce-
nario, use
.
Depending on the installed hardware and the active sub-instrument or instance <i>
only a subset of the described parameter values is allowed. The *RST values and the
mapping of virtual connector names to physical connectors also depend on the active
sub-instrument or instance <i>.
All instruments are equipped with the RF 1 and RF 2 connectors and one RX and TX
module. Additional RF connectors and RX/TX modules are optional.
See also: "Signal Path Settings" in the R&S
CMW user manual, chapter "Remote Con-
trol"
Connector names:
●
RF1C | RF2C | RF3C | RF4C = RF 1 COM to RF 4 COM, front panel
●
RFAC | RFBC = virtual names for the RF COM connectors
●
RF1O | RF3O = RF 1 OUT | RF 3 OUT, front panel
●
RFAO = virtual name for the RF OUT connectors
Parameters:
<RXConnector>
RF1C | RF2C | RF3C | RF4C | RFAC | RFBC
RF connector for the input path
<RXConverter>
RX1 | RX2 | RX3 | RX4
RX module for the input path
Command Reference
深圳德标仪器