1xEV-DO Measurements
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
405
User Manual 1173.9511.02 ─ 11
{<2_SegReliability>
0 | 3 | 4 | 8
The segment reliability indicates whether one of the following
exceptions occurred in this segment:
0:
No error
3:
Signal overflow
4:
Signal low
8:
Synchronization error
If a combination of exceptions occurs, the most severe error is
indicated.
<3_EVMRMS>,
<4_EVMPeak>
Error vector magnitude RMS and peak value.
Range:
0 % to 100 %
Default unit: %
<5_MErrRMS>
Magnitude error RMS value.
Range:
0 % to 100 %
Default unit: %
<6_MErrPEAK>
Magnitude error peak value.
Range:
-100 % to +100 % (AVERage: 0% to 100 %, SDE-
Viation: 0 % to 50 %)
Default unit: %
<7_PErrRMS>
Phase error RMS value.
Range:
0 deg to 180 deg
Default unit: deg
<8_PErrPeak>
Phase error peak value.
Range:
-180 deg to 180 deg (AVERage: 0 deg to 180 deg,
SDEViation: 0 deg to 90 deg)
Default unit: deg
<9_IQOffset>
I/Q origin offset
Range:
-100 dB to 0 dB
Default unit: dB
<10_IQImbalance>
I/Q imbalance
Range:
-100 dB to 0 dB
Default unit: dB
<11_CFreqError>
Carrier frequency error
Range:
-5000 Hz to 5000 Hz
Default unit: Hz
<12_TransTimeErr> Transmit time error.
Range:
-100 µs to 100 µs
Default unit: µs
<13_ATPow1M23>
Access terminal power, measured with a filter bandwidth of 1.23
MHz.
Range:
-100 dBm to 50 dBm
Default unit: dBm
Command Reference
深圳德标仪器
135-1095-0799