1xEV-DO Measurements
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
409
User Manual 1173.9511.02 ─ 11
The number to the left of each result parameter is provided for easy identification of the
parameter position within the result array.
The values described below are returned by
FETCh
commands.
CALCulate
com-
mands return limit check results instead, one value for each result listed below.
For the "Out of Tolerance" and "Code Channel Filter Match Ratio" results retrieved via
the
CURRent
,
AVERage
and
MAXimum
command are identical.
Return values:
<1_Reliabiltiy>
Conventions and General Information
. In list mode, a zero relia-
bility indicator indicates that the results in all measured seg-
ments are valid. A non-zero value indicates that an error occur-
red in at least one of the measured segments.
{<2_SegReliability>
0 | 3 | 4 | 8
The segment reliability indicates whether one of the following
exceptions occurred in this segment:
0:
No error
3:
Signal overflow
4:
Signal low
8:
Synchronization error
If a combination of exceptions occurs, the most severe error is
indicated.
<3_PowOffsetM9>, ...
, <12_PowOffsetM0>,
<13_PowCarrier>,
<14_PowOffsetP0>,
...
,<23_PowOffsetP9>,
Returns the adjacent channel power measured at a series of fre-
quencies.
The frequencies are determined by the offset values defined via
the commands
ues are considered (irrespective of their activation status).
The power offsets <PowOffsetPn> (<PowOffsetMn>) refer to the
average power at the carrier frequency plus (minus) the fre-
quency offset value number n.
Range:
-100 dB to 20 dB
Default unit: dB
<24_ATPowerWide> Access terminal power, measured with the wideband filter.
Range:
-100 dBm to 50 dBm
Default unit: dBm
<25_ATPwNarrow>
Access terminal power, measured with a filter bandwidth of 1.23
MHz.
Range:
-100 dBm to 50 dBm
Default unit: dBm
Command Reference