CONFigure:EVDO:SIGN<i>:LAYer:APPLication:RETap:SMIN:SIZE?
Queries the minimum RETAP test packet size. This is determined by the selected mini-
mum packet size index (
).
Return values:
<MinSize>
Range:
0 bits to 12.288E+3 bits
*RST:
128 bits
Example:
See
Usage:
Query only
Firmware/Software:
V1.0.15.0
Manual operation:
See
"RETAP Configuration > Min / Max Packet Size"
CONFigure:EVDO:SIGN<i>:LAYer:APPLication:RETap:SMAX:INDex
<MaxIndex>
Selects the maximum data rate index for RETAP packets. Use
to query the corresponding
packet size.
Parameters:
<MaxIndex>
Range:
1 to 12
*RST:
1
Example:
See
Firmware/Software:
V1.0.15.0
Manual operation:
See
"RETAP Configuration > Min / Max Packet Size"
CONFigure:EVDO:SIGN<i>:LAYer:APPLication:RETap:SMAX:SIZE?
Queries the packet size for the selected maximum data rate index (
).
Return values:
<MaxSize>
Range:
0 bits to 12.288E+3 bits
*RST:
128 bits
Example:
See
Usage:
Query only
Firmware/Software:
V1.0.15.0
Manual operation:
See
"RETAP Configuration > Min / Max Packet Size"