1xEV-DO Measurements
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
411
User Manual 1173.9511.02 ─ 11
Return values:
<1_Reliability>
Conventions and General Information
. In list mode, a zero relia-
bility indicator indicates that the results in all measured seg-
ments are valid. A non-zero value indicates that an error occur-
red in at least one of the measured segments.
{<2_SegReliability>
The segment reliability indicates whether one of the following
exceptions occurred in this segment:
0:
No error
3:
Signal overflow
4:
Signal low
8:
Synchronization error
If a combination of exceptions occurs, the most severe error is
indicated.
<3_PowOffsetM19>,
... ,
<22_PowOffsetM0>,
<23_PowCarrier>,
<24_PowOffsetP0>,
...
,<43_PowOffsetP19>,
Returns the adjacent channel power measured at a series of fre-
quencies.
The frequencies are determined by the offset values defined via
the commands
All defined offset values are considered (irrespective of their
activation status).
The power offsets <PowOffsetPn> (<PowOffsetMn>) refer to the
average power at the carrier frequency plus (minus) the fre-
quency offset value number n.
Range:
-100 dB to 20 dB
Default unit: dB
<44_ATPowerWide> Access terminal power, measured with the wideband filter.
Range:
-100 dBm to 50 dBm
Default unit: dBm
<45_ATPwNarrow>
Access terminal power, measured with a filter bandwidth of 1.23
MHz.
Range:
-100 dBm to 50 dBm
Default unit: dBm
<46_OutOfTolCount> Out of tolerance result, i.e. percentage of measurement inter-
vals of the statistic count (see
limits, see
.
Range:
0 % to 100 %
Default unit: %
<47_CurStatCount>} Number of evaluated valid slots in this segment.
*RST:
0 to 1000
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V3.2.20