1xEV-DO Measurements
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
297
User Manual 1173.9511.02 ─ 11
Measure on Exception
Specifies whether measurement results that the R&S
CMW identifies as faulty or inac-
curate are rejected. A faulty result occurs e.g. when an overload is detected. In remote
control, the cause of the error is indicated by the "reliability indicator".
●
Off:
Faulty results are rejected. The measurement is continued; the statistical
counters are not re-set. Use this mode to ensure that a single faulty result does not
affect the entire measurement.
●
On:
Results are never rejected. Use this mode e.g. for development purposes, if
you want to analyze the reason for occasional wrong transmissions.
Remote command:
3.3.12 Trigger Settings
The "Trigger" parameters configure the trigger system for both, the multi evaluation
and the OLTR measurement.
For the parameter description refer to
chapter 3.3.7, "Trigger Settings"
3.3.13 OLTR: Limits
The OLTR-specific "Limits" can be set in the configuration dialog of the OLTR mea-
surement.
Fig. 3-31: OLTR limits
Initial Lower Limit
Sets the lower limit for the limit violation calculation. Softkey is also available.
Remote command:
3.3.14 Generator Shortcut
The "Generator Shortcut" parameters configure the GPRF connection for both, the
multi evaluation and the OLTR measurement.
For the parameter description refer to
chapter 3.3.9, "Generator Shortcut"