1xEV-DO Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
225
User Manual 1173.9511.02 ─ 11
Manual operation:
See
"Forward/Reverse Link PER > Max Test Packets Sent"
CONFigure:EVDO:SIGN<i>:RXQuality:FLPFormance:MFRames
<MaxFrames>
CONFigure:EVDO:SIGN<i>:RXQuality:RLPFormance:MFRames
<MaxFrames>
Defines the maximum duration of the "Forward Link Performance" / "Reverse Link Per-
formance" measurement as a number of 26.66 ms CDMA frames.
Parameters:
<MaxFrames>
Range:
1 to 10000
*RST:
1000
Example:
See
Configure Performance (Throughput) Measurements
Firmware/Software:
V2.1.20
Options:
R&S CMW-KS890
Manual operation:
See
"Forward/Reverse Link Throughput > Max Frames"
2.6.11.5
Limit Settings
The following commands define upper limits for "PER" and "Throughput" measure-
ments.
CONFigure:EVDO:SIGN<i>:RXQuality:LIMit:PER:EVALuation
........................................... 225
CONFigure:EVDO:SIGN<i>:RXQuality:LIMit:FLPer:MPER
................................................. 226
CONFigure:EVDO:SIGN<i>:RXQuality:LIMit:RLPer:MPER
.................................................226
CONFigure:EVDO:SIGN<i>:RXQuality:LIMit:FLPer:CLEVel
............................................... 226
CONFigure:EVDO:SIGN<i>:RXQuality:LIMit:RLPer:CLEVel
............................................... 226
CONFigure:EVDO:SIGN<i>:RXQuality:LIMit:PER:EVALuation
<LimitEvaluation>
Defines whether the limits specified for the forward and reverse link PER (Packet Error
Rate) measurements shall be evaluated per carrier or over all carriers. This only
affects multi-carrier evaluations.
Parameters:
<LimitEvaluation>
PERCarrier | ALLCarriers
*RST:
PERC
Default unit: %
Example:
See
Firmware/Software:
V2.1.20
Manual operation:
See
"Multi Carrier Limit Evaluation"
Command Reference