CDMA2000 Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
552
User Manual 1173.9511.02 ─ 11
Pattern ← FCH/SCH0 Configuration
Defines the bit pattern that the pattern generator uses to send to the MS for measure-
ments. This pattern is used if "Pattern Generation" is set to
Fixed
.
Remote command:
Circular Buffer Frames ← FCH/SCH0 Configuration
Sets the number of frames to use in the circular buffer of the FCH and SCH0 when the
random pattern is selected.
Remote command:
Tx On/Off Period ← FCH/SCH0 Configuration
Sets the transmission on | off period in frames of the F-FCH, R-FCH, F-SCH0 and R-
SCH0 when the frame activity is deterministic while performing the test data service.
Remote command:
4.3.8.5
Packet Data Service
Sets packet data service control of the MS.
This feature is only available with DAU, see
chapter 4.2.3, "End to End Packet Data
Fig. 4-46: Packet data service settings
..............................................................................................552
Network Inactivity Timer
Sets when R&S
CMW terminates a PPP session.
Remote command:
MS Dormant Timer
Defines how R&S
CMW sets a MS dormant timer via service option control message.
Remote command:
GUI Reference
深圳德标仪器