1xEV-DO Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
131
User Manual 1173.9511.02 ─ 11
2.5.2.2
Configure PER Measurements
// *************************************************************************
// Define the repetition mode for both directions.
// *************************************************************************
CONFigure:EVDO:SIGN:RXQuality:PER:REPetition SINGleshot
// *************************************************************************
// In multi-carrier measurements, the limits shall be evaluated per carrier
// *************************************************************************
CONFigure:EVDO:SIGN:RXQuality:LIMit:PER:EVALuation PERCarrier
// *************************************************************************
// Forward Link PER measurement configuration: measure until
// 1000 packets have arrived, set the maximum tolerable PER to
// 1% and the minimum required confidence level to 95%.
// *************************************************************************
CONFigure:EVDO:SIGN:RXQuality:FLPer:MTPSent 1000
CONFigure:EVDO:SIGN:RXQuality:FLPer:SCONdition NONE
CONFigure:EVDO:SIGN:RXQuality:LIMit:FLPer:MPER 1
CONFigure:EVDO:SIGN:RXQuality:LIMit:FLPer:CLEVel 95
// *************************************************************************
// Reverse Link PER measurement configuration: lLet the AT send at most
// 1000 test application MAC packets. Stop if either these 1000 packets
// have been sent or the configured confidence level has been reached.
// Set the maximum tolerable PER to 3% and the minimum required confidence
// level to 95%
// *************************************************************************
CONFigure:EVDO:SIGN:RXQuality:RLPer:MPSent 1000
CONFigure:EVDO:SIGN:RXQuality:RLPer:SCONdition MCLexceeded
CONFigure:EVDO:SIGN:RXQuality:LIMit:RLPer:MPER 3
CONFigure:EVDO:SIGN:RXQuality:LIMit:FLPer:CLEVel 95
2.5.2.3
Configure Performance (Throughput) Measurements
// *************************************************************************
// Define the repetition mode for both directions.
// *************************************************************************
CONFigure:EVDO:SIGN:RXQuality:THRoughput:REPetition CONTinuous
// *************************************************************************
// Set the duration
// *************************************************************************
CONFigure:EVDO:SIGN:RXQuality:FLPFormance:MFRames 1000
CONFigure:EVDO:SIGN:RXQuality:RLPFormance:MFRames 1000
Programming