1xEV-DO Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
118
User Manual 1173.9511.02 ─ 11
Adds a comment to the source code of the script.
●
// <remark>
:
Adds a remark to the output of the script.
●
WHILE <query> <> <value>
:
Waits until the <query> returns a certain <value>, e.g. a specific state is reached.
●
WAITKEY <message>
:
Displays a dialog box with a <message> and wait until the box is closed by the
user.
See also: "Remote Control" in the R&S
CMW user manual
...........................................................................................118
................................................................................................ 130
2.5.1 General Configuration
The 1xEVDO signaling application is programmed as follows:
●
The application is controlled by SCPI commands with the following syn-
tax:
...:EVDO:SIGN:...
●
After a
*RST
, the forward signal is switched off.
–
To activate the forward signal use
SOURce:EVDO:SIGN:STATe ON
.
Query the cell state using
SOURce:EVDO:SIGN:STATe:ALL?
. The result
ON,ADJ
indicates that the forward signal is available.
–
To initiate a connection setup use
CALL:EVDO:SIGN:CSWitched:ACTion
CONNect
.
To query the connection states use
FETCh:EVDO:SIGN:CSWitched:STATe?
/
FETCh:EVDO:SIGN:PDATa:STATe?
.
..................................................................................118
................................................................................120
..................................................................................122
...................................................................................122
Configuring the Test Application
........................................................................... 123
Configuring the Test Application Protocol Stack
...................................................123
Sending Date and Time Information to the AT
......................................................127
........................................................................................127
Query Carrier Acquisition Status
...........................................................................128
................................................................................128
Configuring Reverse Power Control Setup
........................................................... 128
Configuring Message Monitoring
.......................................................................... 130
2.5.1.1
Specifying General Settings
// *************************************************************************
// System-Reset
// *************************************************************************
Programming