background image

5.  Catch rate activity will be higher at night. For best catch results it is recommended to keep the unit away from  

 

competing  light sources. 

6.  It is recommended to place the unit at least 20 to 40 feet away from where people will be sitting. 

7.  This unit is all-weather resistant - designed for outdoor use including rainy conditions.  

 

Intended for household and commercial, indoor and outdoor use.  

8.  To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other).  

 

This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug.  

 

If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.

9.  SERVICING OF DOUBLE-INSULATED APPLIANCES - In a double-insulated appliance, two systems of insulation are  

 

provided instead of grounding. No grounding means is provided on a double-insulated appliance, nor should a 

 

means for grounding be added to the appliance. Servicing of a double-insulated appliance requires extreme care  

 

and knowledge of the system and should be done only by qualified service personnel. Replacement parts for a 

 

double-insulated appliance must be identical to those parts in the appliance. The symbol must be identical to those 

 

parts in the appliance. A double-insulated appliance is marked with the words “DOUBLE INSULATION”,  

 

“DOUBLE-INSULATED” or the symbol: 

CLEANING

Frequent cleaning will prolong the life of the unit, ensure fire 

prevention and provide for more efficient operation.

1.  Be sure to clean the unit once per week.

2.  To clean, hold the switch on the revolving rotation door and  

 

twist housing to the “OFF” position. After hearing the “click,”  

 

the machine is turned off. Unplug the unit.

3.  For weekly cleaning, twist the cage clockwise and remove any  

 

buildup from the inside of the retaining cage and fan with the  

 

included cleaning brush.  

4.  For major cleaning, remove the screw securing the fan housing  

 

to the light housing 

(

A

),

 and gently twist to separate. Do not  

 

disconnect wires. Using the cleaning brush, remove dirt and  

 

debris from the fan housing. Once the cleaning process has  

 

been completed, tuck the wires into the channel of the fan  

 housing

 (

D

)

. Align the screw holes and place the light housing  

 

on top of fan housing. Secure with a click and tighten the screw  

 

to the base of the light housing.  

 

IMPORTANT: When replacing the retaining cage –  

 

DO NOT press/push against the screen windows.

5.  Clean prior to off-season storage.  

REPLACING BULB 

Replace with DynaTrap

®

 bulb #41050   

(or equivalent G24 Type - 56V/7W bulb)
The lightbulb life expectancy is approximately 3,000 hours (or about 

4 months), and should be replaced regularly to ensure optimal UV 

effectiveness. Even though the bulb’s light may be visible to you, its 

ability to attract mosquitoes diminishes over time.

1.  Hold the switch on the revolving rotation door and turn it to the  

 

“POWER OFF” position. UNPLUG UNIT, and allow bulb to cool  

 

before replacing. 

2.  Remove the screw securing the fan housing to the light housing  

 

(

A

)

, and gently twist to separate carefully, do not disconnect  

 

wires. Loosen the screw securing the metal bracket  

 

securing the light bulb

 (

B

)

 and remove the metal bracket.  

 

Cover the bulb with a cloth to protect your fingers and hand.  

 

Grasp the bulb (with your hand and fingers protected by the  

 

cloth) and gently pull the bulb from the socket 

(

C

)

3.  Remove any debris from the lamp socket with cleaning brush.  

 

Insert new bulb. Reposition the metal bracket over the base of  

 

the bulb and tighten the screw. Make sure to tuck the wires into 

 

the channel of the light housing so the wires do not get pinched  

 

or cut by the fan 

(

D

)

. Align the screw holes and place the light  

 

housing on top of fan housing. Secure with a “click” and tighten  

 

the screw to the base of the light housing. 

IMPORTANT: READ CAREFULLY

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS

WARNING:

 

when using electric appliances, basic precautions should 

always be followed, including the following:

1.  Please read all instructions before using the DynaTrap

®

 Insect Trap and keep for future reference.

2.  To disconnect, twist housing to the ‘OFF’ position, then remove plug from outlet.

3.  To reduce the risk of injury from moving parts or electric shock, always turn unit off and disconnect plug when  

 

not in use and before servicing or cleaning.

4.  Always unplug before replacing lamp. Replace with same type rated 7-Watt bulbs, DynaTrap

®

 model 41050.

5.  Do not position the unit near heat, gas, oil or other flammable materials.

6.  Place out of reach from children.

7.  To reduce the risk of electrical shock, do not put appliance in water or other liquid.

8.  Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been  

 

dropped or damaged, or if it has been dropped into water or other liquid.

9.  Connect only to a circuit that is protected by a ground-fault circuit-interrupter (GFCI).

10.  Do not insert fingers or any foreign objects into the unit while it is connected to an electrical outlet.

11.  Collected insects within the unit may contribute to fire, so clean insects from the unit frequently.

12.  Do not clean this product with water spray. Do not place where it can fall into water, or near flammable materials.

13.  Do not touch fan while in motion.

14.  Do not abuse cord—never carry or hang unit by cord or yank it to disconnect from receptacle.  

 

Keep cord away from sharp edges.

15.  If using outdoors, use only extension cords with a tag stating, “Suitable for Use with Outdoor Appliances.”

16.  Use only extension cords that have plug and receptacles that match the product plug. Replace or repair damaged cords.

17.  Only use attachments recommended or sold by the manufacturer.

18.  This appliance is provided with double insulation. Use only identical replacement parts.  

 

See instructions or Servicing of Double-Insulated Appliances.

INSTALLATION & OPERATING INSTRUCTIONS

1.  Unpack unit. Save carton for off-season storage (if needed).

2.  Assemble Stand: Pull the cord tight through the pole stand. Turn  

 

base on its side and insert bottom threaded plastic piece into  

 

base, connecting to the threaded plastic cap. Twist threaded 

 

plastic cap clockwise to tighten. Complete installation by aligning 

 

upper and lower support tube and inserting the bar sections. 

 

For more detailed instructions, please refer to assembly guide.

3.   Hold the power switch on the side of the revolving rotation door.  

 

Twist the unit to the “POWER ON” position. When you hear a  

 

“click,” the machine is turned on. 

4.  For best catch results leave unit on at all times, except when  

 

cleaning or servicing.

A0

00

-3

96

.2

01

9.1

4

DT1260-TUN

OWNER’S MANUAL

Thank you for purchasing  

the DynaTrap

® 

insect trap!

This product may be covered by one or more U.S. patents  
or pending patent applications. See wwwDynaTrap.com/patents

TROUBLESHOOTING

Problem:

Possible cause:

Correction:

Bulb does not il-

luminate and fan does 

not spin.

1. No electrical power.

1. Check plug, receptacle and fuse or circuit breaker.

2. Check to make sure power is switched to the “ON” position.

Bulb illuminates, but 

fan does not spin.

1. Shorted fan.

1. UNPLUG UNIT: Examine fan to see that it is free from 

    foreign material, dirt or buildup of dead insects.  

    Clean unit as in “CLEANING” section.

Fan spins, but bulb 

does not illuminate. 

1. Bulb not seated properly.

2. Burnt out bulb.

1. Check sockets for proper bulb seating and alignment.

2. Replace bulb if needed, following instructions under  

   “Replacing Bulb”. 

HOW THE DYNATRAP

®

 INSECT TRAP WORKS

Flying insects are attracted to the unit by the UV light 
and CO2 that is generated by the photo-catalysis 

between the UV lamps and the special TiO2 coating. 

The fan then pulls the insects into the screened base, 

trapping them until they dehydrate and die. The base 

can be removed, allowing the contents to be periodically 

emptied into the trash. Monitor the insects trapped in 

the retaining cage through the see-through screen, and 

empty when compartment becomes full. 

LIMITED WARRANTY

DYNAMIC guarantees to the original purchaser that this product is free from defective materials and workmanship. 

This warranty is limited to remedy any defective part for a period of one year from date of original date of 

purchase. Retain your original receipt as proof of purchase. This warranty does not apply to the light bulb, nor to, 

in our judgment, misuse or abuse. If this unit has been altered, no warranty is in force. This warranty does not 

apply if this unit is purchased outside the United States, excluding Canada and Mexico. In no case shall DYNAMIC 

be liable for any accidental, punitive, consequential, or any other damages of any kind for breach of this or any 

other warranty, expressed or implied, whatsoever. Some states do not allow limitation on how long an implied 

warranty lasts, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal 

rights, and you may also have other rights that vary from state to state.

REPLACEMENT PARTS

41050 

7-Watt Replacement UV Fluorescent Bulb (1 piece)

41053 

Retaining Cage

To see all replacement and accessory parts visit wwwDynaTrap.com.

FOR HOUSEHOLD AND COMMERCIAL, INDOOR AND OUTDOOR USE

This device complies with Performance Standards 
for Light-Emitting Products, 21 DFR, Part 1040, 
Chapter 1, Subchapter J, Radiological health.

Dynamic Solutions Worldwide, LLC

U.S.A. & Canada 

12247 W. Fairview Ave. Milwaukee, WI 53226
1-877-403-TRAP (8727)
[email protected] | www.DynaTrap.com

Mexico

 

Dynatrap Servicios de Mexico S. de R. L. de C.V.
01-800-880-8727 | [email protected]
©2019 Dynamic Solutions Worldwide, LLC

4002907

Summary of Contents for DynaTrap DT1260-TUN

Page 1: ...quid 8 Never operate this product if it has a damaged cord or plug if it is not working properly if it has been dropped or damaged or if it has been dropped into water or other liquid 9 Connect only to a circuit that is protected by a ground fault circuit interrupter GFCI 10 Do not insert fingers or any foreign objects into the unit while it is connected to an electrical outlet 11 Collected insect...

Page 2: ...6 vatios DynaTrap modelo 32050 5 No coloque la unidad cerca de fuentes de calor gas aceite u otros materiales inflamables 6 Mantenga la unidad fuera del alcance de niños 7 Para reducir el riesgo de una descarga eléctrica mantenga la unidad alejada del agua o cualquier otro líquido 8 Nunca haga funcionar la unidad si el cable de corriente eléctrica o la clavija están dañados la unidad no está funci...

Page 3: ...osition After hearing the click the machine is turned off Unplug the unit 3 For weekly cleaning twist the cage clockwise and remove any buildup from the inside of the retaining cage and fan with the included cleaning brush 4 For major cleaning remove the screw securing the fan housing to the light housing A and gently twist to separate Do not disconnect wires Using the cleaning brush remove dirt a...

Page 4: ...ornillo que asegura la carcasa del ventilador y la carcasa del foco A gire las carcasas suavemente para separarlas No desconecte los cables Usando la brocha retire el polvo y los acumulados en la carcasa del ventilador Coloque los cables en el canal de la carcasa del ventilador D Alinee los orificios del tornillo y coloque la carcasa del foco en la parte superior de la carcasa del ventilador Asegú...

Reviews: