Error Code List Chapter4. Cash & Check In Module
4-248
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
I9888
[Retract] A customer gets notes
while retracting those (subnormal).
1. Check the residual media at the
Bundle part (1).
2. Check whether sensors (BDS01,
BDS02, BDS05, BDS07) checking
residual media in the Bundle(1) are
polluted.
3. Execute CCIM initialization.
I9889
[Retract] The number of notes in
the retract box is not consistent
(subnormal).
1. Open the BM2(7) and remove the
residual media at the moving path (6, 7,
8, 9).
2. Execute initialization.
I9893
[Retract]Failure to check the last
note at the termination of mid
transport path while retracting
those.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I98E0
[Retract]]Anomaly of check
information
1. Remove the residual media in the
device.
2. Execute initialization.
I98F1
[Retract]Internal Error while the
main task is operating.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I98FF
[Retract] Failed to move to 3-Way
1 or 3-Way 2 Gate position
1. Open the BM2(7) and BM2(12) and
remove the residual media at the moving
path (7, 8, 9, 10).
2. Execute initialization.
I9901
[Retract] A undefined position has
been entered.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I9902
[Retract]Timeout occurs when
moving to the initial position for
initialization (PRS02 Dark) and the
limit of retries (3 times) is
exceeded.
1. Open the BM3 moving path and
remove the media.
2. If the same fault continuously occur
after checking the device, replace the
PRT Module.
I9903
[Retract]PRS02 sensor is not light-
detected during initialization and
the limit of retries (3 times) is
exceeded.
1. Open the BM3 moving path and
remove the media.
2. If the same fault continuously occur
after checking the device, replace the
PRT Module.
I9904
[Retract] When moving to the
home position, PRS02 sensor is
dark after trying it three times but
the dark point cannot be found.
1. Open the BM3 moving path and
remove the media.
2. If the same fault continuously occur
after checking the device, replace the
PRT Module.
I9905
[Retract] When moving to the
home position, PRS02 sensor is
light after trying it three times but
the light point cannot be found.
1. Open the BM3 moving path and
remove the media.
2. If the same fault continuously occur
after checking the device, replace the
PRT Module.
I9906
[Retract] When moving to the
PREFIRE position, PRS02 sensor
is dark after trying it three times
but the dark point cannot be
found.
1. Open the BM3 moving path and
remove the media.
2. If the same fault continuously occur
after checking the device, replace the
PRT Module.