Chapter4. Cash & Check In Module Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
4-77
Code
Problem Description
Troubleshooting
I3609
[Entry In/Out]Alien media have
sequentially entered to the Reject
part.
1. Reject Door(9) Open
2. Remove the notes and alien materials
in the Reject.
3. If no alien material exists, check
whether the Reject output check sensor
(RJS08) is polluted.
I360A
[Entry In/Out]When media
abnormally access and are piled
at the Reject part, the residual
media exist at the Reject part
(RJS10 Dark).
1. Remove the notes and alien materials
in the Reject output media residual
sensor (RJS10).
2. If no alien material exists, check
whether the sensor is polluted.
I360B
[Entry In/Out]When media
abnormally access and are piled
at the Reject part, the residual
media exist at the Reject part
(RJS08 Dark).
1. Remove the notes and alien materials
in the Reject output check sensor
(RJS08).
2. If no alien material exists, check
whether the sensor is polluted.
I360C
[Entry In/Out]Fault of performing a
undefined processing flow at
Reject.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I36F1
[Entry In/Out]Reject Task force
shutdown.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I3702
[Entry In/Out]Fault of performing a
undefined processing flow at
MICR.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I3703
[Entry In/Out]MICR Task force
shutdown.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I3704
[Entry In/Out]Fault of calling a
undefined command from MICR.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I3706
[Entry In/Out]RCS02 Dark is not
detected when Moving Header is
moving to H.P.
1. Check MICR RCM01 Motor(5)
operation and alien materials.
2. If the same fault continuously occurs
after checking the device, replace the
Recognition(5) Module.
I3707
[Entry In/Out]RCS02 Light is not
detected while initializing MICR.
1. Check MICR RCM01 Motor(5)
operation and alien materials.
2. Check the cable connected to Moving
Header home position(RCS02) sensor.
3. If the same fault continuously occurs
after checking the device, replace the
Recognition(5) Module.
I3708
[Entry In/Out]The first motor is
stopped after running and timeout
occurs while initializing MICR.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I3709
[Entry In/Out]The second motor is
stopped after running and timeout
occurs while initializing MICR.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I370A
[Entry In/Out]The third motor is
stopped after running and timeout
occurs while initializing MICR.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.