Code
Problem Description
Troubleshooting
566GD00
Failure to Lift-up during
Withdrawal Ready.
1. Open the upper unit.
2. Open the customer service module
(CSM) shutter(1)
3.Check the notes and substance inside
of the CSM
566GE00
Failure to Lift-down during
Withdrawal Ready.
1. Open the upper unit.
2. Open the customer service module
(CSM) shutter(1)
3.Check the notes and substance inside
of the CSM
566GF00
Failure to move gate roller to
home position during
Withdrawal Ready.
1. Open the upper unit.
2. Check the knob rotates softly in the
CSM(2)
566M100
Stopper Init error during
Withdrawal Ready.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM
566M300
Shutter close error during
Withdrawal Ready.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM
566M400
Stopper down error during
Withdrawal Ready.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM
566M600
Shutter Close error initializing
stopper during Withdrawal
Ready.
1. Open the upper unit
2. Check knob rotates softly in the
CSM(1)
3. Check inside of CSM
566P100
PP withdrawal(stack) position
movement error during
Withdrawal Ready .
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
566P200
PP deposit position movement
error during Withdrawal
Ready .
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
566P300
PP separate position
movement error during
Withdrawal Ready .
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
566P400
PP lose return position
movement error during
Withdrawal Ready .
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
566P500
PP notes out error during
Withdrawal Ready .
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)