Code
Problem Description
Troubleshooting
520Q300
BMU inter lock error during
Deposit Count.
1. Check Load/Removal of the upper
unit
2. Replace a cherry switch when error
occures
520Q400
BMU removal error during
Deposit Count.
1. Check Load/Removal of the upper
unit
520Q500
Safe door open error during
Deposit Count.
1. Check the safe door open
520Q600
CSM open error during Deposit
Count.
1. Open the upper unit
2. Check to open/close CSM
3. Check the sensors GS011
520Q700
RJC removal error during
Deposit Count.
1. Open the lower unit
2. Open the Mid Transport Path
3. Check the reject CST(21)
Load/Removal
520Q800
BMD inter lock error during
Deposit Count.
1. Check the lower Unit load/removal
2. Replace a cherry switch when error
occures
520Q900
BMD removal error during
Deposit Count.
1. Check the lower Unit load/removal
520QA00
BC open error during Deposit
Count.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Check the lock lever in the BC
520R100
BM message timeout error
during operation ready in
Deposit Count.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
520R200
BM message timeout error
during transaction operation in
Deposit Count.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
520R300
BM message timeout error
during postprocessing to
Deposit Count Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5211500
GS105 dark jam error during
Deposit Count.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Remove substance
6. Check whether the sensor is
contaminated or not if there are No
notes or substance.
5212500
Error occurred by the notes
remained on the Transport
Path (GS105) during Deposit
Count.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance