Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-427
Code
Problem Description
Troubleshooting
5E6B100
Receive notes and position
disorder during Shutter Open.
1. Open the upper unit
2. Open the CSM(1)
3. Remove notes and substance in the
CSM(1)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5E6G100
BP stack position movement
error during Withdrawal Ready
before opening shutter.
1. Open the upper unit
2. Open CSM shutter(1)
3. Check the notes and substance
inside of CSM
5E6G200
BP notes out error during
Withdrawal Ready before
opening shutter.
1. Open the upper unit
2. Open CSM shutter(1)
3. Check the notes and substance
inside of CSM
5E6G300
BP separate position
movement error during
Withdrawal Ready before
opening shutter.
1. Open the upper unit
2. Open CSM shutter(1)
3. Check the notes and substance
inside of CSM
5E6G400
BP separate control error
during Withdrawal Ready
before opening shutter.
1. Open the upper unit
2. Open CSM shutter(1)
3. Check the notes and substance
inside of CSM
5E6G500
BP notes out position error
during Withdrawal Ready
before opening shutter.
1. Open the upper unit
2. Open CSM shutter(1)
3. Check the notes and substance
inside of CSM
5E6G600
Failure to move pickup-roller to
home position during
Withdrawal Ready before
opening shutter.
1. Open the upper unit
2. Check the knob rotates softly in the
CSM(2)
5E6G800
Failure to revert
notes(Separate motor
disorder) during Withdrawal
Ready before opening shutter.
1. Open the upper unit
2. Check the notes and substance in the
CSM(2)
3. Check the knob rotates softly in the
CSM(2)
4. Check the GS660 sensor status
5E6GA00
Failure to move
withdrawal(stack) position of
stack roller(GM605 disorder)
during Withdrawal Ready
before opening shutter.
1. Open the upper unit
2. Check the knob rotates softly in the
CSM(3)
5E6GB00
Failure to move depositposition
of stack roller Stack roller
(GM605 disorder) during
Withdrawal Ready before
opening shutter.
1. Open the upper unit
2. Check the knob rotates softly in the
CSM(3)
5E6GC00
Failure to control stack
roller(GM605 disorder) during
Withdrawal Ready before
opening shutter.
1. Open the upper unit
2. Check the knob rotates softly in the
CSM(3)