![background image](http://html1.mh-extra.com/html/nautilus-hyosung/mx8800/mx8800_manual_3517484561.webp)
Error Code List Chapter4. Cash & Check In Module
4-8
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
I1103
[Initialize]Fault of calling a
undefined command from
Cassette1.
1. Execute CCIM initialization action.
2. Reboot the system when the same
error occurs after initialization.
I1104
[Initialize]Fault of performing a
undefined process flow from
Cassette1.
1. Execute CCIM initialization action.
2. Reboot the system when the same
error occurs after initialization.
I1105
[Initialize]Cassette1 position or
door open fault.
1. Check the Cassette1(14) installation
state and door open state.
2. Check Cassette1 home position
(NCS01) sensor connection cable.
I1106
[Initialize] Fault of causing retry of
moving the Cassette1 Push Plate
Bottom position.
1. Check the jam when moving the push
plate left/right/vertically and manually.
2. Check the Cassette1 push plate
motor (NCM01) running and cable
connection.
I1107
[Initialize]Jam at the sensor
(NCS07) detecting the number of
papers which enter into the
Cassette1.
1. Check residual media or alien
materials at the Cassette1(14) entry and
remove those.
I1108
[Initialize] Fault of causing retry of
moving the Cassette1 Push Plate
top position.
1. Check the arrangement state of the
banknotes in the Cassette1(14).
2. Check the stack position (NCS06) and
the media entry detection (NCS09) prism
state.
3. If the same fault continuously occurs
after checking the device, replace the
Cassette1(14)
I1109
[Initialize] Fault of exceeding the
retries when the Cassette1 Clamp
failed to move to the position
(NCS08 Light).
1. Check the Cassette1 media guide
motor (NCM02) running and cable
connection.
2. If the same fault continuously occurs
after checking the device, replace the
Cassette1(14)
I110A
[Initialize] Fault that the position is
not detected even when the
Cassette1 Clamp is running at the
position (NCS08 Light).
1. Check the Cassette1 media guide
motor (NCM02) running and cable
connection.
2. If the same fault continuously occurs
after checking the device, replace the
Cassette1(14)
I110B
[Initialize] Failure to detect the
bottom (NCS05) when the
Cassette1 Push Plate Stack
moves
1. Check the arrangement state of
banknotes in the Cassette.
2. Check the Stack position sensor
(NCS06) lever operation state.
3. If the Push Plate is not at the bottom,
check the alien materials at the
Cassette1 Bottom sensor(NCS05).
I1203
[Initialize]Fault of calling a
undefined command from
Cassette1.
1. Execute CCIM initialization action.
2. Reboot the system when the same
error occurs after initialization.
I1204
[Initialize]Fault of performing a
undefined process flow from
Cassette2.
1. Execute CCIM initialization action.
2. Reboot the system when the same
error occurs after initialization.
I1205
[Initialize]Cassette2 position of
door open fault
1. Check the Cassette2(15) installation
state and door open state.
2. Check Cassette2 home position
sensor(CCS01) connection cable.