Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-185
Code
Problem Description
Troubleshooting
568HA02
Error GS801B during
Withdrawal Ready.
1. Check GS801B
2. Operate to initialize BRM(Recovery)
568HA03
Error GS801A, GS801B during
Withdrawal Ready.
1. Check GS801A, GS801B
2. Operate to initialize BRM(Recovery)
568HA04
Error GS802A during
Withdrawal Ready.
1. Check GS802A
2. Operate to initialize BRM(Recovery)
568HA05
Error GS801A, GS802A during
Withdrawal Ready.
1. Check GS801A, GS802A
2. Operate to initialize BRM(Recovery)
568HA06
Error GS801B, GS802A during
Withdrawal Ready.
1. Check GS801B, GS802A
2. Operate to initialize BRM(Recovery)
568HA07
Error GS801A, GS801B,
GS802A during Withdrawal
Ready.
1. Check GS801A, GS801B, GS802A
2. Operate to initialize BRM(Recovery)
568HA08
Error GS802B during
Withdrawal Ready.
1. Check GS802B
2. Operate to initialize BRM(Recovery)
568HA09
Error GS801A, GS802B during
Withdrawal Ready.
1. Check GS801A, GS802B
2. Operate to initialize BRM(Recovery)
568HA10
Error GS801B, GS802B during
Withdrawal Ready.
1. Check GS801B, GS802B
2. Operate to initialize BRM(Recovery)
568HA11
Error GS801A, GS801B,
GS802B during Withdrawal
Ready.
1. Check GS801A, GS801B, GS802B
2. Operate to initialize BRM(Recovery)
568HA12
Error GS802A, GS802B
during Withdrawal Ready.
1. Check GS802A, GS802B
2. Operate to initialize BRM(Recovery)
568HA13
Error GS801A, GS802A,
GS802B during Withdrawal
Ready.
1. Check GS801A, GS802A, GS802B
2. Operate to initialize BRM(Recovery)
568HA14
Error GS801B, GS802A,
GS802B during Withdrawal
Ready.
1. Check GS801B, GS802A, GS802B
2. Operate to initialize BRM(Recovery)
568HA15
Error GS801A, GS801B,
GS802A, GS802B during
Withdrawal Ready.
1. Check GS801A, GS801B, GS802A,
GS802B
2. Operate to initialize BRM(Recovery)
568HF03
Error to load shading data of
the CIS during Withdrawal
Ready.
1. Operate shading in the BC CIS
2. Operate to initialize BRM(Recovery)
568HF04
Error to load recognition DB
table during Withdrawal
Ready.
1.Download DB again after delecting all
recognition DB
2. Operate to initialize BRM(Recovery)
568HF05
Error to BC FPGA data
checksum during Withdrawal
Ready.
1. Check to BC FPGA File
2. Operate to initialize BRM(Recovery)
568HF06
Error to BC FPGA
configuration during
Withdrawal Ready.
1. Re-download BC FPGA
2. Change the BC B/D if continuous
error.
568HF07
Error to load to info of BC
FPGA header during
Withdrawal Ready.
1. Re-download BC FPGA
2. Change the BC B/D if continuous
error.
568HF08
Error to FPGA initialize during
Withdrawal Ready.
1. Re-download BC FPGA
2. Change the BC B/D if continuous
error.
568HF09
Error to FPGA Read during
Withdrawal Ready.
1. Re-download BC FPGA
2. Change the BC B/D if continuous
error.