Error Code List Chapter4. Cash & Check In Module
4-26
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
I186D
[Initialize]CST1 store timeout
(Escrow->CST2)
1. Remove the residual media in the
device.
2. Execute initialization.
I186E
[Initialize]CST2 store timeout
(Escrow->CST2)
1. Remove the residual media in the
device.
2. Execute initialization.
I186F
[Initialize] Timeout of checking
residual media in Bundle occurs
during initialization.
1. Remove the residual media in the
device.
2. Execute initialization.
I1870
[Initialize] Failed to rewind while
the Escrow is empty (logical
sensor is empty)
1. Remove the residual media at the
Escrow part (12).
2. Remove the media residual at the
Escrow (ESS01, ESS02, ESS03) and
the pollution.
3. If no alien material exists, check
whether the sensor is polluted.
4. Execute CCIM initialization.
I1871
[Initialize]Deposit reject command
is received when the residual
media are not detected at the
Reject part.
1. Remove the residual media in the
device.
2. Execute initialization.
I1872
[Initialize]Detects residual media
at the Reject part
1. Remove the residual media in the
device.
2. Execute initialization.
I1879
[Initialize]Fault occurs while the
BC part is preparing.
1. Remove the residual media in the
device.
2. Check the BC Cover(3) Lock state.
3. Execute initialization.
I187A
[Initialize]BC response timeout.
1. Check the cable connecting between
Main and BC (Connector CN37).
I187B
[Initialize] The number of notes
which have passed BC is not
consistent with that of Escrow and
Reject.
1. Remove the residual media in the
device.
2. Check the BC Cover(3) Lock state.
3. Execute initialization.
I187C
[Initialize]BC operation is not
completed.
1. Remove the residual media in the
device.
2. Check the BC Cover(3) Lock state.
3. Execute initialization.
I1880
[Initialize] The maximum number
set in the Escrow is reached
(subnormal).
1.No actions taken
I1881
[Initialize] The maximum number
(50) set in the Reject is reached
(subnormal).
1.No actions taken
I1882
[Initialize]Retract logical number is
full (subnormal).
1.No actions taken
I1883
[Initialize]The maximum number of
separable at the Bundle part is
exceeded (subnormal).
1.No actions taken
I1885
[Initialize] A customer gets notes
before retracting those
(subnormal).
1. Check the residual media at the
Bundle part (1).
2. Check whether sensors (BDS01,
BDS02, BDS05, BDS07) checking
residual media in the Bundle(1) are
polluted.
3. Execute CCIM initialization.