Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-542
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5WASX00
Info of Dip-Switch differs from
TCR in the Initial Info Set.
1. Check to Dip Switch 4 - On.
2. Operate to initialize Infomation set
again after setting up AP-SP
3. Restar over AP-SP when same error
occures after re-operating
5WASY00
Missing serial number notes
stack set CST disorder(Small
BRM but RC4 or 5 select)
when Initial Info set.
1. Check the cassette setting up missing
serial number notes
2. Operate to initialize BRM(Recovery)
5WASZ00
Operation mode is not ´
No use´ even through
setting up currency info is 0 in
the Initial Info Set.
1. Operate to initialize Infomation set
again after setting up AP-SP
1. Restar over AP-SP when same error
occures after re-operating
5WBH100
RC1 EEPROM read error
during Initial Info Set.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5WBH200
RC2 EEPROM read error
during Initial Info Set.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5WBH300
RC3 EEPROM read error
during Initial Info Set.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5WBH400
RC4 EEPROM read error
during Initial Info Set.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5WBH500
RC5 EEPROM read error
during Initial Info Set.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5WBH600
RC1 EEPROM write error
during Initial Info Set.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5WBH700
RC2 EEPROM write error
during Initial Info Set.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5WBH800
RC3 EEPROM write error
during Initial Info Set.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5WBH900
RC4 EEPROM write error
during Initial Info Set.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5WBHA00
RC5 EEPROM write error
during Initial Info Set.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization