Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-204
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5707N00
Error occurred by the notes
disorder on the GS032 during
Withdrawal .
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5707P00
Error occurred by the notes
disorder on the GS033 during
Withdrawal .
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5707Q00
Error occurred by the notes
disorder on the GS034 during
Withdrawal .
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5707W00
Error occurred by the notes
disorder on the GS802 during
Withdrawal .
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove notes and substance in the
BC(5)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
570D100
Continous Reject error during
Withdrawal .
1. Check the Rejected denomination
during withdrawal(Including
denomination which did not set up in the
cassette)
570D200
Count Limit Exceed error of
Maximum Reject in the
Withdrawal .
1. Check the Rejected denomination
during withdrawal(Including
denomination which did not set up in the
cassette)
570D300
Outside of denomination error
during Withdrawal .
1. Check the Rejected denomination
during withdrawal(Including
denomination which did not set up in the
cassette)
570D400
CST denomination disorder
error during Withdrawal .
1. Check the Rejected denomination
during withdrawal(Including
denomination which did not set up in the
cassette)
570D500
Double notes disorder error
during Withdrawal .
1. Open the upper unit
2. Open the CSM shutter
3. Check the seperate part status of
CSM