![background image](http://html1.mh-extra.com/html/nautilus-hyosung/mx8800/mx8800_manual_3517484116.webp)
Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-112
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5401K00
GS703 dark jam error during
Deposit Cancel.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Rotate a knob of TE(12)
4. Remove notes and substance in the
Rear Transport Path(11)
5401M00
GS031 dark jam error during
Deposit Cancel.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5401N00
GS032 dark jam error during
Deposit Cancel.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5401P00
GS033 dark jam error during
Deposit Cancel.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5401Q00
GS034 dark jam error during
Deposit Cancel.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5401W00
GS802 dark jam error during
Deposit Cancel.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove notes and substance in the
BC(5)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5402100
Error occurred by the notes
remained on the GS801 during
Deposit Cancel.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove the notes and the substance
from the Front Transport Path (4)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance