Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-527
Code
Problem Description
Troubleshooting
5T6P300
PP separate position transfer
error during Module Test.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
5T6P400
PP lose Return position
transfer error during Module
Test.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
5T6P500
PP notes out position transfer
error during Module Test.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
5T6P600
PP notes arrange error during
Module Test.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
5T6P700
PP separate control(during
separating) error during
Module Test.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
5T6P800
PP stack control(during
stacking) error during Module
Test.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
5T6P900
Error of reverting notes during
Module Test.
1. Open the upper unit
2. Check the notes and substance in the
CSM(2)
3. Check the knob rotates softly in the
CSM(2)
4. Check the knob rotates softly in the
CSM(3)
5T6PA00
PP preparation stop error
during Module Test.
1. Operate to initialize BRM(Recovery)
5TAE100
Received operation command
without Initial Info Set during
Module Test.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5TAE200
Status on not operation
receiption command during
Module Test.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5TAE400
Module Test transaction was
executed without Initializing
after power on .
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5TAE600
Error to received Module Test
command. during TE Button
Operating.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization