Error Code List Chapter4. Cash & Check In Module
4-208
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
I7E0D
[Deposit OK]JError occurred by
the Transport Path on the
AAS03
1. Open the alignment(4) cover and
remove the residual media and alien
materials.
2. Initialize the device.
3. Check the alignment(4) cover lock
state.
I7E0E
[Deposit OK]JError occurred by
the Transport Path on the
RCS01
1. Remove the internal media and alien
materials in the Recognition(5).
2. Initialize the device.
3. If the same fault continuously occurs
after checking the device, replace the
Recognition(5) Module.
I7E0F
[Deposit OK]JError occurred by
the Transport Path on the
FDS07
1. Open the BM2(7) Upper Guide and
remove the residual media and alien
material.
2. Open the BM3 moving path to remove
the residual media.
I7E10
[Deposit OK]JError occurred by
the Transport Path on the
FDS23
1. Open the BM2(7) Upper Guide and
remove the residual media and alien
material.
2. Open the BM3 moving path to remove
the residual media.
I7E11
[Deposit OK]JError occurred by
the Transport Path on the
FDS09
1. Open the BM2(7) and then remove
the residual media and alien materials.
2. Check the 3Way-Gate1 operation
state (FDM06)
I7E12
[Deposit OK]JError occurred by
the Transport Path on the
FDS12
1. Open the third moving path (8) and
then remove the residual media and
alien materials.
2. Check the 3Way-Gate2 operation
state (FDM07)
I7E13
[Deposit OK]JError occurred by
the Transport Path on the
FDS18
1. Open the BM2(7) and remove the
residual media at the moving path (6)
and Cassette1(14) entry.
2. Execute initialization.
I7E14
[Deposit OK]JError occurred by
the Transport Path on the
NCS07
1. Check residual media or alien
materials at the Cassette1(14) entry and
remove those.
I7E15
[Deposit OK]JError occurred by
the Transport Path on the RJS08
1. Remove the residual media in the
device.
2. Execute initialization.
I7E16
[Deposit OK]JError occurred by
the Transport Path on the
PRS01
1. Open the third moving path (8) and
then remove the residual media and
alien materials.
2. Check the 3Way-Gate2 operation
state (FDM07)
I7E17
[Deposit OK]JError occurred by
the Transport Path on the
FDS16
1. Open the BM3 moving path and then
remove the residual media and alien
materials.
2. Check the arrangement state of
banknotes in the RT box.
I7E18
[Deposit OK]JError occurred by
the Transport Path on the
RTS02
1. Open the BM2(7) and remove the
residual media at the moving path (6, 7,
8, 9).
2. Remove the notes in the Retract Box.
3. Execute initialization.