Error Code List Chapter4. Cash & Check In Module
4-4
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
97I0055
A user is preventing proper
operation of the device.
1. Restart the ccim sp
97I0056
The data structure passed as an
input parameter although valid for
this service class is not supported
by this Service Provider or device.
1. Restart the ccim sp
97I0057
Some devices are capable of
identifying a malicious physical
attack which attempts to defraud
valuable information or media. In
these cases, this error code is
returned to indicate the user is
attempting a fraudulent act on the
device.
1. Restart the ccim sp
97I0058
The requested operation is not
valid at this time or in the devices
current state.
1. Restart the ccim sp
97I1302
The Retract bin is already full.
1. Remove Cash in Retract bin.
97I1307
There were too many items
inserted. The
cash-in stacker is full.
1. Remove Cash in stacker.
2. Restart the ccim sp
97I1308
The position specified is not
supported.
1. Re-Set the supported input
parameters.
97I1310
The safe door is open. This device
requires
the safe door to be closed in order
to perform
a WFS_CMD_CIM_CASH_IN
command.
1. Check a Safe Door
97I1312
Shutter failed to open. In the case
of explicit shutter control the
application may have failed to
open the shutter before issuing
the command.
1. Check a Shutter.
97I1313
Shutter was already open.
1. Check a Shutter.
97I1315
The cash unit number specified is
not valid.
1. Re-Set the supported input
parameters.
97I1316
There were no items to cash-in.
1. Check device status.
97I1317
The CIM is in an exchange state.
1. Change no exchange state.
97I1318
There is no exchange active.
1. Change exchange state.
97I1323
Items were present at the output
position at the start of the
operation, but were removed
before the operation was complete
- some or all of the items were not
retracted.
1. Check device status.
97I1325
A Cash-In transaction is active.
1. Change no active state.
97I1326
There is no cash-in transaction
active.
1. Execute CASH_IN_START command.
97I1328
The input or output position is not
empty.
1. Check device status.
97I1335
The retract area specified in
usRetractArea is not supported.
1. Re-Set the supported input
parameters.
97I1339
The hardware requires that the
cash unit is empty before allowing
changes.
1. the cash unit is empty before allowing
changes