Error Code List Chapter4. Cash & Check In Module
4-102
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
I4335
[Deposit Count/Check]WET NOTE
detected
1. Check the inside of the Bundle(1).
2. Remove the alien materials in the
Bundle(1).
3. If no alien material exists in the
Bundle(1),
Check and remove the alien materials
in the internal sensors.
4. If no alien material exists, check
whether the Bundle sensor is polluted
I4340
[Deposit Count/Check] BDS07
Light fault when separating media.
1. Check the inside of the Bundle(1).
2. Remove the notes and alien materials
in the Bundle(1).
3. If no alien material exists in the
Bundle(1),
Check and remove the alien materials
in the internal sensors.
4. If no alien material exists, check
whether the Bundle sensor is polluted
I4341
[Deposit Count/Check]BDS08,09
Light Timeout (100 ms) fault when
separating media.
1. Check the inside of the Bundle(1).
2. Remove the notes and alien materials
in the Bundle(1).
3. If no alien material exists in the
Bundle(1),
Check and remove the alien materials
in the internal sensors.
4. If no alien material exists, check
whether the Bundle sensor is polluted
I4342
[Deposit Count/Check]FDS01
Light Timeout (140 ms) fault when
separating media.
1. Check the inside of the Bundle(1).
2. Remove the notes and alien materials
in the Bundle(1).
3. If no alien material exists in the
Bundle(1),
Check and remove the alien materials
in the internal sensors.
4. If no alien material exists, check
whether the Bundle sensor is polluted
I4343
[Deposit Count/Check]FDS03 and
04 Light Timeout (500 ms) fault
when separating media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM Separation and Send Check
(FDS01) sensor.
3. If no alien material exists in the SCM
Separation and Send Check (FDS01)
sensor,
Check whether the sensor is polluted.
I4344
[Deposit Count/Check]FDS02 and
05 Light Timeout (88 ms) fault
when separating media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM Separation and Send Check
(FDS01) sensor and the Bundle.
3. If no alien material exists in the SCM
Separation and Send Check (FDS01)
sensor,
Check whether the sensor is polluted.