Chapter4. Cash & Check In Module Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
4-7
Code
Problem Description
Troubleshooting
I0B04
[Control/Bulk]Jam at the Recog
detection sensor (RCS01).
1. Remove the internal media and alien
materials in the Recognition(5).
2. Initialize the device.
3. If the same fault continuously occurs
after checking the device, replace the
Recognition(5) Module.
I0B05
[Control/Bulk]Jam at the Align
detection sensor (AAS05)
1. After opening the BM2(7) moving
path, open the Alignment(4) Guide2 to
remove media and alien materials.
2. Initialize the device.
3. If the same fault continuously occurs
after checking the device, replace the
Alignment(4) Module.
I0B06
[Control/Bulk]Jam at the Align
entry detection sensor (AAS06).
1. Open the alignment(4) cover and
remove the residual media and alien
materials.
2. Initialize the device.
3. Check the alignment(4) cover lock
state.
I0B07
[Control/Bulk]Jam at Recog exit
path sensor (FDS07)
1. Open the BM2(7) Upper Guide and
remove the residual media and alien
material.
2. Open the BM2(7) moving path to
remove the residual media.
I0B09
[Control/Bulk]Jam at the second
moving path sensor (FDS09).
1. Open the BM2(7) and then remove
the residual media and alien materials.
2. Check the 3Way-Gate1 operation
state (FDM06)
I0B12
[Control/Bulk]Jam at the 3Way2
control sensor (FDS12)
1. Open the third moving path (8) and
then remove the residual media and
alien materials.
2. Check the 3Way-Gate2 operation
state (FDM07)
I0B15
[Control/Bulk]Jam at the Escrow
entry sensor (FDS15)
1. Open the BM3 moving path and then
remove the residual media and alien
materials.
I0B16
[Control/Bulk]Jam at the RT Box
entry detection sensor (AAS03)
1. Open the BM3 moving path and then
remove the residual media and alien
materials.
2. Check the arrangement state of
banknotes in the RT box.
I10C1
[Initialize] Receives undefined
USB CONTROL command.
1. Execute CCIM initialization action.
2. Reboot the system when the same
error occurs after initialization.
I10C2
[Initialize]A wrong size is received
during USB CONTROL PIPE
communication.
1. Execute CCIM initialization action.
2. Reboot the system when the same
error occurs after initialization.
I10C3
[Initialize]The size of USB bulk
data is 0 or not the multiple of 64.
1. Execute CCIM initialization action.
2. Reboot the system when the same
error occurs after initialization.
I10CF
[Initialize]Fault of transmitting the
same seq of SP.
1. Execute CCIM initialization action.
2. Reboot the system when the same
error occurs after initialization.