Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-235
Code
Problem Description
Troubleshooting
577G400
No detect the front end in the
tape during Withdrawal.
1.Open upper Unit
2. Check the notes remain in the TE(12)
3. Check the color of tape´s front
end is black in the TE(12)
4. Remove notes remain in the TE
577G500
Detect the front end in the
tape during Withdrawal.
1.Open upper Unit
2. Check the notes remain in the TE(12)
3. Check the color of tape´s front
end is black in the TE(12)
4. Remove notes remain in the TE
577G600
No detect the front end in the
tape during Withdrawal.
1.Open upper Unit
2. Check the notes remain in the TE(12)
3. Cheeck whether black tape is wrap
with a drum in the TE(12)
4. Remove notes remain in the TE
577G700
Detect the rear end in the tape
during Withdrawal.
1.Open upper Unit
2. Check the notes remain in the TE(12)
3. Cheeck whether black tape is wrap
with a drum in the TE(12)
4. Remove notes remain in the TE
577J100
TE drum full during
Withdrawal.
1. Open the upper unit
2. Check the notes remain in the TE(12)
3. Remove notes remain in the TE
577J300
Normal end is not possible
during Withdrawal.
1. Operate to initialize BRM(Recovery)
577R100
TE message timeout error
during operation ready in the
Withdrawal.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
577R200
TE message timeout error
during transaction operation int
the Withdrawal.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
577R300
TE message timeout error
during postprocessing of
Withdrawal Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
577RJ00
TE message timeout error
during Stop Ready Withdrawal.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
578HA01
Error GS801A during
Withdrawal.
1. Check GS801A
2. Operate to initialize BRM(Recovery)
578HA02
Error GS801B during
Withdrawal.
1. Check GS801B
2. Operate to initialize BRM(Recovery)
578HA03
Error GS801A, GS801B during
Withdrawal.
1. Check GS801A, GS801B
2. Operate to initialize BRM(Recovery)
578HA04
Error GS802A during
Withdrawal.
1. Check GS802A
2. Operate to initialize BRM(Recovery)
578HA05
Error GS801A, GS802A during
Withdrawal.
1. Check GS801A, GS802A
2. Operate to initialize BRM(Recovery)
578HA06
Error GS801B, GS802A during
Withdrawal.
1. Check GS801B, GS802A
2. Operate to initialize BRM(Recovery)
578HA07
Error GS801A, GS801B,
GS802A during Withdrawal.
1. Check GS801A, GS801B, GS802A
2. Operate to initialize BRM(Recovery)