Code
Problem Description
Troubleshooting
5702J00
Error occurred by the notes
remained on the GS619 during
Withdrawal .
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5702K00
Error occurred by the notes
remained on the GS703 during
Withdrawal .
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Rotate a knob of TE(12)
4. Remove notes and substance in the
Rear Transport Path(11)
5702M00
Error occurred by the notes
remained on the GS031 during
Withdrawal .
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5702N00
Error occurred by the notes
remained on the GS032 during
Withdrawal .
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5702P00
Error occurred by the notes
remained on the GS033 during
Withdrawal .
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5702Q00
Error occurred by the notes
remained on the GS034 during
Withdrawal .
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5702W00
Error occurred by the notes
remained on the GS802 during
Withdrawal .
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove notes and substance in the
BC(5)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance