![background image](http://html1.mh-extra.com/html/nautilus-hyosung/mx8800/mx8800_manual_3517484325.webp)
Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-321
Code
Problem Description
Troubleshooting
5AUS100
USB sequence number
duplicate error during Retract
CSM.
1. Restart over AP-SP
5AUS300
USB command data length
error during Retract CSM.
1. Check USB connection
2. Operate to initialize BRM(Recovery)
5B00100
GS801 light jam error during
Retract TE.
1. Open the upper unit.
2. Open the customer service module
(CSM)
3. Open the BC(5)
4.Remove notes and substance in the
Front Transport Path(4)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5B00200
GS002 light jam error during
Retract TE.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Rotate the knob of the Front
Transport Path(4)
5. Remove the Jam between BC(5) and
Front Transport Path(4).
5B00300
GS003 light jam error during
Retract TE.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Open the Rear Transport Path(6)
4. Remove the Jam between Rear
Transport Path(11) and Rear Transport
Path(6).
5B00400
GS004 light jam error during
Retract TE.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Remove the cassette not received(9)
4. Remove the Jam between Rear
Transport Path(8) and Rear Transport
Path(11).
5B00500
GS005 light jam error during
Retract TE.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Remove the Jam between TE(12)
and Rear Transport Path(11).
5B00600
GS006 light jam error during
Retract TE.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Remove the cassette not received(9)
4. Remove the Jam between Rear
Transport Path(7) and Rear Transport
Path(11).
5B00A00
GS021 light jam error during
Retract TE.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Rotate the knob of the Rear Transport
Path(4)
5. Remove notes in BC
5B00B00
GS022 light jam error during
Retract TE.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove the Jam on the Mid
Transport Path(13).