Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-411
Code
Problem Description
Troubleshooting
5D5J300
RC5 full check failure during
Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Check the stage status after open the
recycle cassette(E)
5. Check contamination status of the
GS512 sensor.
5D5R100
RC5 message timeout error
during operation ready in the
Initialize.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D5R200
RC5 message timeout error
during transaction operation in
the Initialize.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D5R300
RC5 message timeout error
during postprocessing to
Initialize Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D5S100
Undefined return value of RC5
during Initialize.
1. Operate to initialize BRM(Recovery)
5D5S200
Undefined command of RC5
during Initialize.
1. Operate to initialize BRM(Recovery)
5D62100
Notes remains error in the
CSM during Initialize.
1. Open the upper unit
2. Open the CSM(1)
3. Remove notes and substance in the
CSM(1)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5D62400
Undefined command of CSM
error during Initialize.
1. Operate to initialize BRM(Recovery)
5D62500
The status of notes remain in
the CSM changed status of no
notes in the CSM during
Initialize.
1. Open the upper unit
2. Open CSM shutter(1)
3. Check the notes and substance
inside of CSM
4. Check the sensors related with error
5D62600
The status of no notes in the
CSM changed The status of
notes remain in the CSM
during Initialize.
1. Open the upper unit
2. Open CSM shutter(1)
3. Check the notes and substance
inside of CSM
4. Check the sensors related with error
5D62Z00
CSM notes remains semi OK
when Initialize.
Return Notes to customer(Semi OK
Code)
5D6G100
BP stack position movement
error during Initialize.
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
5D6G200
BP notes out error during
Initialize.
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM