Code
Problem Description
Troubleshooting
5VBH800
RC3 EEPROM write error
when received System Info
Read Command.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5VBH900
RC4 EEPROM write error
when received System Info
Read Command.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5VBHA00
RC5 EEPROM write error
when received System Info
Read Command.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5VBHB00
RC1 EEPROM data verify
error when System Info Read.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5VBHC00
RC2 EEPROM data verify
error when System Info Read.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5VBHD00
RC3 EEPROM data verify
error when System Info Read.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5VBHE00
RC4 EEPROM data verify
error when System Info Read.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5VBHF00
RC5 EEPROM data verify
error when System Info Read.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5VBHG00
No detect inter lock when RC
EEPROM R/W during System
Info Read.
1. Check the lower unit status of inter
lock
2. Exchange or clean the inter lock
sensor if occur same error
5VBHH00
Fail to check DPC Sensor
because not to detect inter lock
during System Info Read.
1. Check the lower unit status of inter
lock
2. Exchange or clean the inter lock
sensor if occur same error
5VBHQ00
RC1 Dip-Switch read error
when received System Info
Read Command
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization.
5VBHR00
RC2 Dip-Switch read error
when received System Info
Read Command
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization.
5VBHS00
RC3 Dip-Switch read error
when received System Info
Read Command
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization.
5VBHT00
RC4 Dip-Switch read error
when received System Info
Read Command
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization.
5VBHU00
RC5 Dip-Switch read error
when received System Info
Read Command
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization.