Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-484
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5KA2W00
Status of remaining notes on
the during Transport Path
(GS802) before the operation
during Withdrawal Reject.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove notes and substance in the
BC(5)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5KAA100
Status of UTC removal before
Run during Withdrawal Reject.
1. Open the upper unit
2. Check removal of the cassette not
received(9)
5KAA200
Status of TE open before the
operation during Withdrawal
Reject.
1. Open the upper Unit
2. Check open/close of TE(12)
5KAA300
Status of BMU inter lock
detachment before the
operation during Withdrawal
Reject.
1. Check Load/Removal of the upper
unit
2. Replace a cherry switch when error
occures
5KAA400
Status of BMU detachment
before the operation during
Withdrawal Reject.
1. Check Load/Removal of the upper
unit
5KAA600
Status of CSM open before the
operation during Withdrawal
Reject.
1. Open the upper Unit
2. Check open/close of CSM
3. Check sensor GS011
5KAA700
Status of RJC detachment
before the operation during
Withdrawal Reject.
1. Open the lower unit
2. Open the Mid Transport Path
3. Check the reject CST(21)
Load/Removal
5KAA800
Status of BMD inter lock before
the operation during
Withdrawal Reject.
1. Check the lower Unit load/removal
2. Check the lower unit status of inter
lock
3. Exchange the cherry switch or clean
the inter lock sensor(or exchange) if
occur same error
5KAA900
Status of BMD detachment
before the operation during
Withdrawal Reject.
1. Check the lower Unit load/removal
2. Check the lower unit status of inter
lock
3. Exchange the cherry switch or clean
the inter lock sensor(or exchange) if
occur same error
5KAAA00
Status of BC open before the
operation during Withdrawal
Reject.
1. Open the upper unit
2. Check the lock lever in the BC
5KAAC00
Status of RJC full before the
operation during Withdrawal
Reject.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove reject cassette(21)
4. Remove notes after checking notes
full in the cassette
5. Check whether the sensor is
contaminated or not if a cassette is
empty.
5KAAL00
Abnormal status of
RC(Removal, Not Used,
Withdrawal RC) to stack during
Withdrawal Reject.
1. Open the lower unit
2. Check status of RC (Note Used,
Failure Status)
3.Operate to initialize BRM(Recovery)