Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-296
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5A07500
Error occurred by the notes
disorder on the GS005 during
Retract CSM.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A07600
Error occurred by the notes
disorder on the GS066 during
Retract CSM.
1. Open the forge note cassette(10)
2. Open the TE(Temporary Escrow) (12)
3. Remove notes and substance in the
Rear Transport Path(7)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A07A00
Error occurred by the notes
disorder on the GS021 during
Retract CSM.
1. Open the lower unit
2. Remove notes and substance in the
Mid Transport Path(13)
3. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A07B00
Error occurred by the notes
disorder on the GS022 during
Retract CSM.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the banknotes and the
foreign substance from the reject
cassette (19)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A07G00
Error occurred by the notes
disorder on the GS614 during
Retract CSM.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
CSM(3)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A07H00
Error occurred by the notes
disorder on the GS618 during
Retract CSM.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A07J00
Error occurred by the notes
disorder on the GS619 during
Retract CSM.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance