Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-157
Code
Problem Description
Troubleshooting
54BS200
RBU connection MI error
during Deposit Cancel.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
54US100
USB Sequence duplicated
number error during Deposit
Cancel.
1. Restart over AP-SP
54US300
USB command data length
error during Deposit Cancel.
1. Check USB connection
2. Operate to initialize BRM(Recovery)
5602100
Error occurred by the notes
remained on the GS801 during
Withdrawal Ready.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove the notes and the substance
from the Front Transport Path (4)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5602200
Error occurred by the notes
remained on GS002 during
Withdrawal Ready.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove the notes and the substance
from the Front Transport Path (4)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5602300
Error occurred by the notes
remained on GS003 during
Withdrawal Ready.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Open the Rear Transport Path(6)
4. Remove notes and substance in the
Rear Transport Path(6)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5602400
Error occurred by the notes
remained on GS004 during
Withdrawal Ready.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Open the cassette not received(9)
4. Remove notes and substance in the
Rear Transport Path(8)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5602500
Error occurred by the notes
remained on GS005 during
Withdrawal Ready.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance