Error Code List Chapter4. Cash & Check In Module
4-254
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
I9C08
[Retract]BCS02 Light
Timeout(500ms) fault when
separating media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM and the Bundle.
3. Check the SCM Half Lock state.
4. If no alien material exists in the SCM,
check whether the SCM internal media
detection sensors (FDS01, FDS02,
FDS03, FDS04, FDS05) are polluted.
I9C09
[Retract]BCS01,BCS02 Light
Timeout(500ms) fault when
separating media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM and the Bundle.
3. Check the SCM Half Lock state.
4. If no alien material exists in the SCM,
check whether the SCM internal media
detection sensors (FDS01, FDS02,
FDS03, FDS04, FDS05) are polluted.
I9C0A
[Retract]FDS15 Light Timeout
fault
1. Open the third moving path (8) and
then remove the residual media and
alien materials.
2. Check the 3Way-Gate2 operation
state (FDM07)
I9C0B
[Retract]AAS06 is not reached
(Light JAM) fault when
separating media.
1. BC(3) and SCM(2) Open
2. Remove the notes and alien materials
in the BC, SCM. and Bundle.
3. Check the BC and SCM Half Lock
state.
4. If no alien material exists in the BC
and SCM, check whether the SCM
internal media detection sensors
(FDS01, FDS02, FDS03, FDS04,
FDS05) are polluted.
I9C0C
[Retract]AAS05 Light Timeout
fault
1. Alignment(4) Open
2. Alignment(4) part residual media
I9C0D
[Retract]AAS03 Light Timeout
fault
1. Alignment(4) Open
2. Alignment(4) part residual media
I9C0E
[Retract]RCS01 Light Timeout
fault
1. Alignment(4) Open
2. Alignment(4) part residual media
I9C0F
[Retract]FDS07 Light Timeout
fault
1. Remove the internal media and alien
materials in the Recognition(5).
2. If the same fault continuously occurs
after checking the device, replace the
Recognition(5) Module.
I9C10
[Retract]FDS23 Light Timeout
fault
1. Remove the internal media and alien
materials in the Recognition(5).
2. If the same fault continuously occurs
after checking the device, replace the
Recognition(5) Module.
I9C11
[Retract]FDS09 Light Timeout
fault
1. Open the BM2(7) Upper Guide and
remove the residual media and alien
material.
2. Open the BM3 moving path to remove
the residual media.
I9C12
[Retract]FDS12 Light Timeout
fault
1. Open the BM2(7) and then remove
the residual media and alien materials.
2. Check the 3Way-Gate1 operation
state (FDM06)