Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-194
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
56AR700
Message timeout error of RBU
response during Withdrawal
Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
56ARC00
BC reponse message timeout
error during Withdrawal Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
56ARJ00
Message timeout error during
Stop Ready in the Withdrawal
Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
56BS000
RBU communication timeout
error during Withdrawal Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
56BS100
RBU connection sequence
error during Withdrawal Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
56BS200
RBU connection MI error
during Withdrawal Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
56US100
USB Sequence duplicated
number error during
Withdrawal Ready.
1. Restart over AP-SP
56US300
USB command data length
error during Withdrawal Ready.
1. Check USB connection
2. Operate to initialize BRM(Recovery)
5700100
GS801 light jam error during
Withdrawal .
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove the notes and the substance
from the Front Transport Path (4)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5700200
GS002 light jam error during
Withdrawal .
1. Open the lower unit
2. Remove notes and substance in the
Mid Transport Path(13)
3. Check whether the sensor is
contaminated or not if there are No
notes or substance
5700300
GS003 light jam error during
Withdrawal .
1. Open the upper unit
2. Open the CSM and TE(12)
3. Open BC(5) and Rear Transport
Path(6)
4. Remove the Jam between BC(5) and
Rear Transport Path(6).
5700500
GS005 light jam error during
Withdrawal .
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Open the Rear Transport Path(6)
4. Remove Jam between the Rear
Transport Path(6) and the TE(12).