![background image](http://html1.mh-extra.com/html/nautilus-hyosung/mx8800/mx8800_manual_3517484028.webp)
Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-24
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
518HG21
Error of power on during
receiving BCU ready command
in the Deposit Ready .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
518HG22
Error of DD sensor initialization
during receiving BCU ready
command in the Deposit
Ready .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
518HG23
Error of set up for DD sensor
DAC during receiving BCU
ready command in the Deposit
Ready .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
518HG24
Error of encoder set-up mode
during receiving BCU ready
command in the Deposit
Ready .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
518HG36
Error of recognized mode
during receiving BCU mode
command in the Deposit
Ready .
1. Check to the recoginzed mode
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred (message timeout error) after
initialization
518HG37
Error of transaction setting
during receiving BCU mode
command in the Deposit
Ready .
1. Check to the transaction setting
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred (message timeout error) after
initialization
51A2100
Status of remaining notes on
the Transport Path (GS801)
before the operation during
Deopsit Ready.
1. Open the upper unit.
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove notes and substance in the
Front Transport Path(4)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
51A2200
Status of remaining notes on
the Transport Path (GS002)
before the operation during
Deopsit Ready .
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove the notes and the substance
from the Front Transport Path (4)
5. Check whether the sensor is
contaminated or not if there are No