Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-226
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
574J200
RC4 empty during Withdrawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (D)
4. Check the notes remain after Open
the recycle cassette door(D)
5. Fill up the Notes if there are no notes
6. Check whether the sensor is
contaminated if there are Notes.
574K100
Requried separate note count
of RC4 is 0 during Withdrawal.
1. Operate to initialize BRM(Recovery)
574NL00
Case of below is semi OK.
When RC4 setting count is 0
during withdrawal, separation
is set to sop. Actual count is
more than remain count,
remain count is more than
require count..
1. Check RC4 actual count and SPL
screen count.
2. Setting RC4 count match actual
count.
3. Operate to initialize BRM(Recovery)
574R100
RC4 message timeout error
during operation ready in the
Withdrawal.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
574R200
RC4 message timeout error
during transation operation in
the Withdrawal .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
574R300
RC4 message timeout error
during postprocessing of
Withdrawal Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
574RJ00
RC4 message timeout error
during Ready Stio in the
Withdrawal .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
574S100
Undefined return value of RC4
during Withdrawal .
1. Operate to initialize BRM(Recovery)
574S200
Undefined command of RC5
during Withdrawal.
1. Operate to initialize BRM(Recovery)
574S300
An inoperable command,
Withdrawal Ready is issued to
RC4 during Withdrawal Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
574SZ00
Failure to separate required
Notes in the RC4 while
withdrawal stops to sepatate 0
count(NO available RC
cassette to separate).
1. Check the remained count in the RC
5750500
GS505 light jam error during
Withdrawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Put down the Stage after open the
recycle cassette door (E)
5. Remove notes and substance using
jam removal Knob in the upper side