
Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-521
Code
Problem Description
Troubleshooting
5S8R900
BC message timeout error
during receiving BCU
counterfeil-bill-table
registration/ inquire command
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5S8S100
Receive abnormal MI from BC
during receiving BCU
counterfeil-bill-table
registration/ inquire command
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5S8S200
Receive abnormal BCC from
BC during receiving BCU
counterfeil-bill-table
registration/ inquire command
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5S8S400
Receive ETC. error from BC
during receiving BCU
counterfeil-bill-table
registration/ inquire command..
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5S8S900
Receive retry error from BC
during receiving BCU
counterfeil-bill-table
registration/ inquire command
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5SAE100
Received operation command
without Initial Info Set during
receiving BCU counterfeil-bill-
table registration/ inquire
command
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5SAE200
Status on not operation
receiption command during
receiving BCU counterfeil-bill-
table registration/ inquire
command
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5SAE300
Received operation command
without System Info Read
during receiving BCU
counterfeil-bill-table
registration/ inquire command
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5SAE400
receiving BCU counterfeil-bill-
table registration/ inquire
command transaction was
executed without Initializing
after power on .
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5SAE600
Error to received BCU
counterfeil-bill-table
registration/ inquire command.
during TE Button Operating.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5SAEE00
RBU RS485 communication
sequence disorder during
receiving BCU counterfeil-bill-
table registration/ inquire
command
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5SAEF00
RBU RS485 connection line
disorder during receiving BCU
counterfeil-bill-table
registration/ inquire command
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization