Error Code List Chapter4. Cash & Check In Module
4-14
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
I1360
[Initialize] Residual fault in the
SCM and BC.
1. BC(3) and SCM(2) Open
2. Remove the notes and alien materials
in the BC, SCM. and Bundle.
3. Check the BC and SCM Half Lock
state.
4. If no alien material exists in the BC
and SCM, check whether the SCM
internal media detection sensors
(FDS01, FDS02, FDS03, FDS04,
FDS05) are polluted.
I1369
[Initialize] Residual fault in the
SCM and BC.
1. BC(3) and SCM(2) Open
2. Remove the notes and alien materials
in the BC, SCM. and Bundle.
3. Check the BC and SCM Half Lock
state.
4. If no alien material exists in the BC
and SCM, check whether the SCM
internal media detection sensors
(FDS01, FDS02, FDS03, FDS04,
FDS05) are polluted.
I1379
[Initialize] Residual fault in the
SCM and BC.
1. BC(3) and SCM(2) Open
2. Remove the notes and alien materials
in the BC, SCM. and Bundle.
3. Check the BC and SCM Half Lock
state.
4. If no alien material exists in the BC
and SCM, check whether the SCM
internal media detection sensors
(FDS01, FDS02, FDS03, FDS04,
FDS05) are polluted.
I13D2
[Initialize] Ultrasonic sensor does
not operate.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
3. Check whether the SCM internal
ultrasonic sensor (FDS06) is polluted
when the same error occurs after
rebooting.
I13D3
[Initialize]BC Module response is
timeout.
1. Check the cable connecting between
Main and BC (Connector CN37).
I13D4
[Initialize] Short media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM and the Bundle.
3. Check the SCM Half Lock state.
4. If no alien material exists in the SCM,
check whether the SCM internal media
detection sensors (FDS01, FDS02,
FDS03, FDS04, FDS05) are polluted.
I13D8
[Initialize]Narrow media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM and the Bundle.
3. Check the SCM Half Lock state.
4. If no alien material exists in the SCM,
check whether the SCM internal media
detection sensors (FDS01, FDS02,
FDS03, FDS04, FDS05) are polluted.