Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-482
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5KA2300
Status of remaining notes on
the during Transport Path
(GS003) before the operation
during Withdrawal Reject.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Open the Rear Transport Path(6)
4. Remove notes and substance in the
Rear Transport Path(6)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5KA2400
Status of remaining notes on
the during Transport Path
(GS004) before the operation
during Withdrawal Reject.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Open the cassette not received(9)
4. Remove notes and substance in the
Rear Transport Path(8)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5KA2500
Status of remaining notes on
the during Transport Path
(GS005) before the operation
during Withdrawal Reject.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5KA2600
Status of remaining notes on
the during Transport Path
(GS006) before the operation
during Withdrawal Reject.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Open the cassette not received(9)
4. Remove notes and substance in the
Rear Transport Path(8)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5KA2A00
Status of remaining notes on
the during Transport Path
(GS021) before the operation
during Withdrawal Reject.
1. Open the lower unit
2. Remove notes and substance in the
Mid Transport Path(13)
3. Check whether the sensor is
contaminated or not if there are No
notes or substance
5KA2B00
Status of remaining notes on
the during Transport Path
(GS022) before the operation
during Withdrawal Reject.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the banknotes and the
foreign substance from the reject
cassette (19)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5KA2G00
Status of remaining notes on
the during Transport Path
(GS614) before the operation
during Withdrawal Reject.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
CSM(3)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance