Code
Problem Description
Troubleshooting
5D07Q00
Error occurred by the notes
disorder on the GS034 during
Initialize.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5D07W00
Error occurred by the notes
disorder on the GS802 during
Initialize.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove notes and substance in the
BC(5)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5D0DR00
Error of failure to synchronizing
recognition during Initialize .
1. Operate to initialize BRM(Recovery)
5D0DS00
Error of failure to synchronizing
recognition during Initialize .
1. Operate to initialize BRM(Recovery)
5D0DT00
Error of failure to synchronizing
recognition during Initialize .
1. Operate to initialize BRM(Recovery)
5D0DU00
Error of failure to synchronizing
recognition during Initialize .
1. Operate to initialize BRM(Recovery)
5D0DV00
Error of failure to synchronizing
recognition during Initialize .
1. Operate to initialize BRM(Recovery)
5D0DW00
Error of failure to synchronizing
recognition during Initialize .
1. Operate to initialize BRM(Recovery)
5D0DX00
Error of failure to synchronizing
recognition during Initialize .
1. Operate to initialize BRM(Recovery)
5D0DY00
Error of failure to synchronizing
recognition during Initialize .
1. Operate to initialize BRM(Recovery)
5D0F100
GM001 motor step out return
during Initialize.
1. Open the upper unit
2. Check the Front Transport Path(4)
knob rotates softly
3.Check remained Notes and substance
in the upper Transport Path
4. Check the sensor GS804 status
5D0F200
GM002 motor step out return
during Initialize.
1. Open the upper unit
2. Check the Rear Transport Path(8)
knob rotates softly
3.Check remained Notes and substance
in the upper Transport Path
4. Check the sensor GS007 status
5D0F400
GM004 motor step out return
during Initialize.
1. Open the lower unit
2. Check the knob rotates in the Mid
Transport Path(20)
3. Check the notes and substance
inside of the Mid Transport Path
4. Check the sensor GS023
5D0F500
Decreased encoder count of
GM001 moter less than
previous values during
Initialize.
1. Operate to initialize BRM(Recovery)