![background image](http://html1.mh-extra.com/html/nautilus-hyosung/mx8800/mx8800_manual_3517484052.webp)
Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-48
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5251500
GS505 dark jam error during
Deposit Count.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Put down the Stage after open the
recycle cassette door (E)
5. Remove substance
6. Check whether the sensor is
contaminated or not if there are No
notes or substance.
5252500
Error occurred by theNotes
remained on the Transport
Path (GS505) during Deposit
Count.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Put down the Stage after open the
recycle cassette door (E)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5257500
Error occurred by the notes
remained on the Transport
Path (GS505) during Deposit
Count.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove notes and substance in the
recycle cassette(18)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
525GB00
Encoder Sensor(GS507) for
Feed Motor failed to detect
Light status when Feed Motor
runs in stacking direction
during Deposit Count.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #5 and
open its door.(E)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS507 works fine if
there is nothing jammed.
525GC00
Encoder Sensor(GS507) for
Feed Motor failed to detect
Dark status when Feed Motor
runs in stacking direction
during Deposit Count.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #5 and
open its door.(E)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS507 works fine if
there is nothing jammed.
5262100
Notes remained error in the
CSM during Deposit Count.
1. Open the upper unit
2. Open the CSM(1)
3. Remove notes and substance in the
CSM(1)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5262200
Separate Note does not exist
in the CSM during Deposit
Count.
1. Open the upper unit
2. Open the CSM(1)
3. Check the notes and substance
inside of CSM
4. Check the sensors related with error