Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-308
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5A6B900
Detecting 2 counts of separate
disorder during Retract CSM.
1. Open the upper unit
2. Open the CSM(1)
3. Remove notes and substance in the
CSM(1)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A6BA00
Exceeded 200 counts limit
error during Retract CSM.
1. Open the upper unit
2. Open the CSM(1)
3. Remove notes and substance in the
CSM(1)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A6BC00
Separate disorder light jam
during Retract CSM.
Return Notes to customer(Semi OK
Code)
5A6BE00
Separate note does exist in the
CSM Separation unit after
complete separation during
Retract CSM.
1. Open the upper unit
2. Open the CSM(1)
3. Remove notes and substance in the
CSM(1)
4. Check whether the sensor is
contaminated or not if there are No
notes of substance
5A6G100
BP stack position movement
error during Retract CSM.
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
5A6G200
BP notes out error during
Retract CSM.
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
5A6G300
BP separate position
movement error during Retract
CSM.
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
5A6G400
BP separate control error
during Retract CSM.
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
5A6G500
BP notes out position error
during Retract CSM.
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
5A6G600
Failure to move pickup-roller to
home position during Retract
CSM.
1. Open the upper unit
2. Check the notes and substance in the
CSM(2)
3. Check the knob rotates softly in the
CSM(2)
4. Check the GS660 sensor status
5A6G700
Separate gap control error
during Retract CSM.
1. Open the upper unit
2. Check the notes and substance in the
CSM(2)
3. Check the knob rotates softly in the
CSM(2)