Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-230
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
575G800
Failure to RC5 push pressure
movement during Withdrawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Check the upper side of the recycle
cassette
575GA00
RC5 solenoid echo error
withdrawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Reload the recycle cassette (E) after
removing recycle cassette
4. Replace the cassette when same
error occurs
575GB00
Encoder Sensor(GS507) for
Feed Motor failed to detect
Light status when Feed Motor
runs in stacking direction
during Withdrawal.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #5 and
open its door.(E)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS507 works fine if
there is nothing jammed.
575GC00
Encoder Sensor(GS507) for
Feed Motor failed to detect
Dark status when Feed Motor
runs in stacking direction
during Withdrawal.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #5 and
open its door.(E)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS507 works fine if
there is nothing jammed.
575J200
RC5 empty during Withdrawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Check the notes remain after Open
the recycle cassette door(E)
5. Fill up the Notes if there are no notes
6. Check whether the sensor is
contaminated if there are Notes.
575K100
Requried separate note count
of RC5 is 0 duringWithdrawal.
1. Operate to initialize BRM(Recovery)
575NL00
Case of below is semi OK.
When RC5 setting count is 0
during withdrawal, separation
is set to sop. Actual count is
more than remain count,
remain count is more than
require count..
1. Check RC5 actual count and SPL
screen count.
2. Setting RC5 count match actual
count.
3. Operate to initialize BRM(Recovery)
575R100
RC5 message timeout error
during operation ready in the
Withdrawal .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
575R200
RC5 message timeout error
during transation operation in
the Withdrawal .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization