Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-421
Code
Problem Description
Troubleshooting
5DAA400
Status of BMU removal before
the operation error during
Initialize.
1. Check Load/Removal of the upper
unit
5DAA600
Status of CSM open before the
operation during Initialize.
1. Open the upper Unit
2. Check open/close of CSM
3. Check sensor GS011
5DAA700
Status of RJC removal before
the operation during Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Check the reject CST(21)
Load/Removal
5DAA800
Status of BMD inter lock
detachment before the
operation during Initialize.
1. Check the lower Unit load/removal
2. Check the lower unit status of inter
lock
3. Exchange the cherry switch or clean
the inter lock sensor(or exchange) if
occur same error
5DAA900
Status of BMD removal before
the operation during Initialize.
1. Check the lower Unit load/removal
2. Check the lower unit status of inter
lock
3. Exchange the cherry switch or clean
the inter lock sensor(or exchange) if
occur same error
5DAAA00
Status of BC Open before the
operation during Initialize.
1. Open the upper unit
2. Check the lock lever in the BC
5DAAP00
After error occurred by the
RC1 path, detect note at
GS105 during Initialize
1. Remove Note.
2. Replace RC1 if same error occures
during Initilize
5DAAQ00
After error occurred by the
RC2 path, detect note at
GS205 during Initialize
1. Remove Note.
2. Replace RC2 if same error occures
during Initilize
5DAAR00
After error occurred by the
RC3 path, detect note at
GS305 during Initialize
1. Remove Note.
2. Replace RC3 if same error occures
during Initilize
5DAAS00
After error occurred by the
RC4 path, detect note at
GS405 during Initialize
1. Remove Note.
2. Replace RC4 if same error occures
during Initilize
5DAAT00
After error occurred by the
RC5 path, detect note at
GS505 during Initialize
1. Remove Note.
2. Replace RC5 if same error occures
during Initilize
5DAE100
Received operation command
without Initial Info Set during
Initialize.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5DAE200
Status on not operation
receiption command during
Initialize.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5DAE300
Received operation command
without System Info Read
during Initialize.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5DAE600
Error to received Initialize
during TE Button Operating.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization