Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-543
Code
Problem Description
Troubleshooting
5WBHB00
RC1 EEPROM data verify
error when Initial Info set.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5WBHC00
RC2 EEPROM data verify
error when Initial Info set.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5WBHD00
RC3 EEPROM data verify
error during Initial Info Set.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5WBHE00
RC4 EEPROM data verify
error when Initial Info set.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5WBHF00
RC5 EEPROM data verify
error when Initial Info set.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5WBHG00
No detect inter lock when RC
EEPROM R/W during Initial
Info Set.
1. Check the lower unit status of inter
lock
2. Exchange or clean the inter lock
sensor if occur same error
5WBR000
RBU response timeout during
Initial Info Set.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5WBR700
RBU response message
timeout error during Initial Info
Set.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5WBS000
RBU communication timeout
error when Initial Info set.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5WBS100
RBU connection sequence
error when Initial Info set.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5WBS200
RBU connection MI error when
Initial Info set.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5WBST00
RTC time setting error during
Initial Info Set.
1. Operate to initialize BRM(Recovery)
5WUS100
USB sequence number
duplicate error when Initial Info
set.
1. Restart over AP-SP
5WUS300
USB command data length
error when Initial Info set.
1. Check USB connection
2. Operate to initialize BRM(Recovery)
5ZUS000
Failure in certification stage 1.
1. Restart over AP-SP
5ZUS100
Failure in certification stage 2.
1. Restart over AP-SP
5ZUS200
USB received data
descrambling error.
1. Restart over AP-SP